Kaye Validator AVS
The Kaye Validator AVS (Advanced Validation System) combines accurate sensor measurements with all GMP requirements for calibration and traceability to national standards, while generating compliant reports and managing the validated assets and validation equipment. The Validator AVS offers improved hardware features, an easy to use data handling concept and an intuitive, user-friendly software interface.
Reducing Your Cost of Ownership
With our integrated validation system and improved data management concept, the Kaye Validator AVS saves time and money by simplifying the entire validation process.
Lifting Validation to the Next Level
The Kaye Validator AVS introduces a completely new validation concept. The AVS console will be the common platform for all validation products. It is dedicated for validation tasks only – so no worries about operating systems. The Software is preloaded – with a customized interface for validation equipment, simplifying the validation process.
Features
Validator AVS
- Enhanced data handling and redundancy (4-levels)
- Expanded input capacity, types, and range
- Improved scan time 2/sec for 48 inputs (EN554/ISO17665)
- Stand-alone operation with Console docking station
Validator AVS Console
- Hardened, rugged Console pre-loaded with all Kaye software
- Easy-to-operate / state-of-the art intuitive user interface
- Ethernet/ WiFi/ Docking Station connections
- Asset centric concept for process equipment and Kaye hardware
- Console capable of running existing Kaye product software.
- Improved Reporting Analysis Tool –backward compatible
- Simplified validation (GAMP-5)
Applications
- Steam Sterilizers (Autoclaves)
- Dry Heat Sterilizers
- Steam in Place (SIP)
- Water Cascade/Fall Sterilizers
- Incubators
- Stability Chambers
- Freezers
- Freeze Dryer/Lyophilisation
- Vessels
Specifications
Analog Input | Up to 48 |
Thermocouples | Type T, J, K,E,B,R,N,S: 0.1°C; T+ limited range 0.01°C resolution |
Scanning Speed | 36 channel in 1 sec and 48 channels in 2 Sec |
Internal Memory | 4 gb for data collection |
Input Impedance | 10KΩ. Source greater than 10KΩ produces open circuit indication |
Common Mode Rejection | 160 db (8 inputs/sec) @ line frequency 145 db (12 inputs/sec) @ line frequency 140 db @ DC |
Max. Common Mode Voltage | 100V pk ch-to-ch350V pk ch-to ch to frame ground |
Normal Mode Rejection | 82 db @ 60 Hz (8 inputs/sec)69 db @ 60 Hz (12 inputs/sec) |
Voltage Input | 0 to 10 VDC |
Resolution | 1:72,000 |
Voltage Input Accuracy | 30 days: ±(0.003% of reading + 2 counts + 4 microvolts) 1 year: ±(0.006% of reading + 2 counts + 4 microvolts) |
Sensitivity | 0.5 microvolts/count on most sensitive range |
Voltage Temp. Coef. | ±(0.1 microvolts + 0.001% reading)/°C |
Compensator Temp. Coef. | ±0.01°C per °C |
Input Terminal Temperature Non-uniformity |
±0.1°C from calibrated terminal |
Input Ranges | -6 to 30mV, -12 to 60mV, -60 to 300mV, -2 to 10V |
Environmental | Temperature: 0 to 50°C (32 to 122°F) Relative humidity: 95% non-condensing |
Power | 90 to 250 VAC, 50/60 Hz |
Fuse Rating | 4A Slow Blow |
Size | 190H X 411W X 381 mm D (457 mm with SIM) 7.5 in H x 16.2 in W x 15 in D (18 in with SIM) |
Weight | 10.60 kg (23.4 lbs) |
Battery | Lithium ion with minimum 3 hours of battery backup |